www.siouxchief.comSupplyDrainage SupportINSTALLATION GUIDEStreamLine Linear Drain TM
9 www.siouxchief.com8. Secure FlashingA. Seal Drain BaseLift out ashing. Remove tape, leaving tape over drain hole only.Apply a 1/8" continu
www.siouxchief.com 1010. Install Clamping CollarAlign collar with drain base under ashing. Press rmly. Starting at one end, insert 5/8" scr
11 www.siouxchief.com14. Install Backer Board and Wall WaterproongNote: TCNA guidelines require waterproong or a vapor membrane be instal
www.siouxchief.com 1220. Re-Install StrainerNote: Strainer attachment holes are not symmetrical. If screws do not align with holes in drain base,
13 www.siouxchief.comCleaning DrainTo clean drain, remove 3 screws in top of strainer. Clear any hair or other obstructions from drain.Remove Stra
www.siouxchief.com 14More than 50 years ago, Sioux Chief started manufacturing rough plumbing products. Today, we still do — right in the heart of
File No. 7249PMG 1065www.siouxchief.comA.1/13 STREAMLINE INSTALLATION INSTRUCTIONS#IS-823
1 www.siouxchief.comPre-PlanningBe certain to gather all required tools and materials required prior to installation.Sub-oor Caution: Sub-oor mu
www.siouxchief.com 2Drain SizesConrm Drain Size, Waste Pipe Type and Waste Pipe LocationDrain hole is off-set to accommodate oor joist location.
3 www.siouxchief.com1. Wall PreparationBlockingBlocking between studs may be needed for ashing and membrane attachment prior to drain installatio
www.siouxchief.com 4Must Fit Flush to Sub-FloorWaste PipeOption B: Waste Pipe Pre-InstalledDry t drain base over location of existing waste pipe.
5 www.siouxchief.com5. Fasten Drain Base to Sub-FloorFor Concrete Sub-Floor A & B For Wood Sub-Floor B onlyA. Mark for AnchorsDry t drain bas
www.siouxchief.com 6Making CornersTucked Corner (when space is available between studs) Fold and crease to size. Tuck shower pan liner into space
7 www.siouxchief.comDrain at Partial Width Curb Flashing must turn up the walls a minimum of 3” above shower curb and 6” above oor in showers wi
www.siouxchief.com 8Drain at Curb-less Entry Flashing must turn up the walls a minimum of 3" above shower curb and 6" above oor in sho