BE SURE TO CHECK EVERY CRIMP
JOINT! Every crimp joint should be
checked with the GO/NO GO Gauge. If
the designated GO slot ts over and will
rotate around the crimped ring, you have
made a proper crimp. If the crimped ring
will t in the NO GO Gauge or will not t
in the GO Gauge, you must cut the crimp
joint off and make a new connection.
YOU’LL NEED
GO/NO GO Gauge
Slide the PEX crimp ring over the end
of the PEX tube leaving about ¼″ of the
tube showing. Insert the tting into the
end of the tube. BE SURE the crimp ring
is centered over the PEX barb.
All of the information you’ll need
to plan and install PEX plumbing
in your home.
Cut tube off square (90°)
with a tube cutter.
YOU’LL NEED
Tube Cutter
More about PEX Crimp Connections
Can be used with both hot and cold drinking water lines or with
hydronic (radiant) heating.
Insert ttings can be installed behind walls, but cannot be buried in concrete.
Use the Home Run system or install in a continuous loop.
PEX crimp rings are made of annealed copper. Sioux Chief’s PEX V-Sleeve is made
of Stainless Steel.
PEX and PB ttings and crimp rings are not interchangeable.
All Sioux Chief ttings and rings are manufactured to the ASTM Standard F1807
Specication for Metal Insert Fittings Utilizing a Copper Crimp Ring for SDR 9 Cross-
linked Polyethylene (PEX) Tubing, and are compatible with any and all ttings and rings
manufactured to this same standard. All Sioux Chief plastic ttings are made to the
ASTM F2159 specication for plastic insert ttings. Sioux Chief’s V-Sleeve connection is
made to the ASTM F877 standard for hot and cold PEX systems utilizing SDR plastic tubing.
12
PEX INSTALLATION GUIDE – 10/11 © 2011 SIOUX CHIEF MFG.
Note: sleeves and crimp rings are to be used
with either ASTM F1807 or F2159 ttings along
with the appropriate tool.
Center the jaws of the correct size
crimp tool over the crimp ring or sleeve.
Be sure the tool is held STRAIGHT and
close the jaws completely. CRIMP/
PRESS ONE TIME ONLY! If you do not
get a proper crimp connection the rst
time, cut the tting off and start from
the beginning.
YOU’LL NEED
Compression/Crimp Tool
Slide the PEX sleeve over the end of
the PEX tube fully. Insert the tting into
the end of the tube. BE SURE the tting
is inserted fully into the pipe.
www.siouxchief.com
SupplyDrainage Support
12 PEX Installation Tips
Making Crimp Connections
STEP
1
STEP
2
STEP
2
STEP
3
STEP
4
Installation Guide
Page view 0
1 2 3 4 5 6

Summary of Contents

Page 1 - Making Crimp Connections

BE SURE TO CHECK EVERY CRIMP JOINT! Every crimp joint should be checked with the GO/NO GO Gauge. If the designated GO slot ts over and will rotate ar

Page 2 - Why Plumb with PEX?

Easy to InstallPEX tube is joined with an easy to install and test ‘crimp’ system — no solvent welding with messy chemicals, no chance of re hazard p

Page 3 - Planning Manifold Locations

Cut out roughly 10″ to 12″ of copper piping. Let excess water drain from the system and deburr cut ends of copper tube.YOU’LL NEED Copper cutt

Page 4 - Transitioning from CPVC

Using CPVC solvent cement, glue on two CPVC × PEX Adapters. Wipe off excess glue. YOU’LL NEED CPVC Cement CPVC PrimerCut out roughly 10″ to 12″ of

Page 5 - www.siouxchief.com 5

Running PEX TubingExtreme Temperatures and SunlightKeep PEX tube away from extreme temperatures — 12″ away from recessed lighting and 6″ away from gas

Page 6 - www.siouxchief.com 7

Cut the spun-closed end off of the stub out, then deburr and clean the outside of the tube with sand cloth.YOU’LL NEED Copper cutting /deburring tool